Meter Testing & Accuracy

Surrey implements a quality assurance program to ensure the metered billings are accurate and equitable. Each meter is tested in the factory before they are installed in water consumer’s properties.

An ongoing meter testing program, performed in accordance with the America Water Waste Association, is conducted to ensure that the meter readings remain accurate within the provision of City’s Water Bylaw, which stipulates the accuracy of meters shall be between 95% and 105%.

In 2012 and 2013, the City of Surrey has tested 531 meters in single family homes and 835 meters in Multi-Family (MF), Institutional, Commercial and Industrial (ICI) Properties. Below is the summary of results.

Summary of Test Result for Meters in Single Family Homes

 

Total Meter Tested

Number of Meters with accuracy limits 95% - 105%

Number of Meters with accuracy below 95% (in favour of consumer)

Number of Meters with accuracy above 105% (in favour of the City)

531 504 504 27
Average Accuracy 98.43% 74.05% 0

Summary of Test Result for Meters in MF & ICI Properties

 

Total Meter Tested

Number of Meters with accuracy limits 95% - 105%

Number of Meters with accuracy below 95% (in favour of consumer)

Number of Meters with accuracy above 105% (in favour of the City)

 835  620  212  3
 Average Accuracy  98.49%   63.87%  106.77%